Flowmeter

Summary



TypeFlowmeter
VendorDIGITEN
Modelunknown
S/NN/A
ID Prefixflowmt
CORIOLIX IDflowmt000001
ClassFlowthrough
Location
Condition
Configuration
Native Sample RateNone Hz
UDP Port(s)30309 None
EnabledFalse
 


Image Not Available
 
 

General Description



Digiten FL-408 flowmeter. Measures flow of water.

 
 

Data Collection Specs

Native Data Feed
Signal Type Analog
Communication Type Frequency
Serial Details
Baud Rate
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Start Commands
Polled Serial Commands
Ethernet Details
MAC Address
IP Address
Protocol
Source File Details
Path
Filename
Native Data Format
Native Data Description
Native Data Type
Start of Message Characters
End of Message Characters
Sample Data Message 42
Message Parser Format ['^(?P<frequency>\d+)$']
Data Processing
Data Processing Script NoTransformation
Data Rates
Native Sample Rate None Hz
Shipboard Network Packet Rate None Hz
Ship to Shore Rate None Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address 192.168.0.255
Port 30309
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source
 

Parameters


Quantity Flow Rate (l/minute) Frequency (Hz)
Plot Color
 
 
Parameter Full Name Water Flow Rate Raw Frequency
Parameter Short Name Flow Rate Frequency
Parameter Standard Name XXXXXX XXXXXX
SAMOS Data Category
Description Raw pulse frequency output from the flowmeter in pulses/second.
Processing Status post processed raw
Processing Symbol flow_rate frequency
Diagnostic False True
IOOS Category Other Other
Units l/minute Hz
Data Type ubyte ushort
Gross Minimum Value 0.0 l/minute 0.0 Hz
Gross Maximum Value None l/minute None Hz
Recommended Minimum Value None l/minute None Hz
Recommended Maximum Value None l/minute None Hz
Global Minimum Value None l/minute None Hz
Global Maximum Value None l/minute None Hz
Local Minimum Value None l/minute None Hz
Local Maximum Value None l/minute None Hz
Lower Detection Limit None l/minute None Hz
Saturated Value None l/minute None Hz
Bad Data Value None l/minute None Hz
Resolution None l/minute None Hz
Accuracy +/- None l/minute +/- None Hz
Precision None l/minute None Hz
Binning Type linear linear
Online Display Format 3.1f f6.0
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power None - None V AC
Ideal Power None V AC
Operating Current None - None mA @ None V AC
Analog Output None - None
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth None - None m
Operating Temperature None - None degree_C
Lamp Life None days
Response Time None seconds
Additional Time Offset None seconds
Physical Status
Current Location installed
Current Status in use
Physical Condition
Physical Configuration
Software Version
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level primary
Enabled False
Vessel Installation Location
Vessel sav
Vessel Location
Location Coordinates (meters)
Sensor Orientation
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Nov 08 2024 22:25:25     Romsos, Chris     sensor specs update     enabled changed from [True] to [False]    
Nov 07 2024 19:15:25     Romsos, Chris     sensor specs update     enabled changed from [True] to [False]    
Nov 06 2024 23:49:53     Romsos, Chris     sensor specs update     transmit_port changed from [None] to [30309]    
Nov 06 2024 23:49:53     Romsos, Chris     sensor specs update     transmit_ip changed from [] to [192.168.0.255]    
Nov 06 2024 23:49:52     Romsos, Chris     sensor specs update     location_text changed from [Forward Machinery Room] to []    
Nov 06 2024 23:49:52     Romsos, Chris     sensor specs update     responsible_party changed from [UGA] to []    
Nov 06 2024 23:49:52     Romsos, Chris     sensor specs update     owner changed from [UGA] to []    
Nov 06 2024 23:49:52     Romsos, Chris     sensor specs update     processing_script changed from [Flowmeter] to [NoTransformation]    
May 07 2024 22:02:29          sensor specs update     responsible_party changed from [] to [UGA]    
May 07 2024 22:02:29          sensor specs update     owner changed from [] to [UGA]    
May 07 2024 21:38:26          sensor specs update     text_regex_format changed from [] to [['^(?P<frequency>\d+)$']]    
May 07 2024 21:38:26          sensor specs update     sample_data_message changed from [] to [42]    
May 07 2024 21:28:06          sensor specs update     processing_script changed from [NoTransformation] to [Flowmeter]    
May 07 2024 21:28:06          sensor specs update     comm_type changed from [] to [Frequency]    
May 07 2024 21:28:06          sensor specs update     signal_type changed from [] to [Analog]    
May 06 2024 16:12:11          sensor specs update     processing_script changed from [] to [NoTransformation]    
Apr 29 2024 22:45:10          sensor specs update     vendor changed from [Not Applicable] to [DIGITEN]    
Apr 29 2024 22:12:32          new sensor     Initial submission of sensor metadata.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A:
 
Maintenance B:
 
Maintenance C:
 
Calibration
 
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
 
 
User Guides & Documents

Date Version Author Type Document Access
 
 
Ownership

Quantity Value
Owner
Responsible Party
Purchase Date
Acquire Date
Acquire Condition
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company DIGITEN
Website https://www.digiten.shop
Phone None provided
Email sale@digit-en.com
Shipping N/A
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA